Need a reliable Air Heater of a special design? We specialize in low to moderate volume runs of specialized air heaters. These heaters are made from the finest Nickel Chrome wire. The coils are combined with the proper mica or ceramic carrier supports in a stainless steel or aluminum frame as determined by temperature. All electrical connections are high quality screw and nut with ceramic bushings. Heaters can also be supplied with thermostats, thermo cut outs, and other protective and control devices. Resistance and Hypot are carefully monitored for proper performance.
High Volume - Moderate Temperature
This Maximum Flow Air Heater design is encased within a 2 3/8"O.D. tube with a cross frame heating element for minimum resistance to airflow. It has a practical operating range of up to 200 CFM with temperatures up to 600°F (315°C).
Standard items listed below.
Length | Cat. No. | Dia. | Wattage | Voltage | Watts/Inch | Weight | Terminals |
6" | MFA-6F-1 | 2 3/8" | 600 | 120 | 150 | .05 | S&N; w/enclosure |
10" | MFA-10F-1 | 2 3/8" | 1000 | 120 | 125 | 1.25 | S&N; w/enclosure |
12" | MFA-12F-2 | 2 3/8" | 375 | 120 | 38 | 1.50 | S&N; w/enclosure |
12" | MFA-12F-2 | 2 3/8" | 1500 | 240 | 150 | 1.50 | S&N; w/enclosure |
14" | MFA-14F-2 | 2 3/8" | 500 | 120 | 42 | 1.75 | S&N; w/enclosure |
14" | MFA-14F-2 | 2 3/8" | 2000 | 240 | 166 | 1.75 | S&N; w/enclosure |
Moderate Volume - High Temperature
This heavy-duty heater design is for continuous high temperature operations up to 1200°F (650°C), while supplying a good flow rate up to 50 CFM. This heater is suited for vacuum and pressure environments, as well as other applications where heavy-duty construction is desirable. This unit is enclosed in 2" schedule 40 S.T. S.T. pipe.
Length | Cat. No. | Dia. | Wattage | Voltage | Watts/Inch | Weight | Terminals |
12" 12" 24" 24" |
HDA-2-12 HDA-2-12-2 HDA-2-24 HDA-2-24-2 |
2 3/8" 2 3/8" 2 3/8" 2 3/8" |
375 1500 750 3000 |
120 240 120 240 |
158 158 140 140 |
7.0 7.0 12.5 12.5 |
S&N; w/enclosure S&N; w/enclosure S&N; w/enclosure S&N; w/enclosure |
Moderate Heat - Moderate Volume
Length | Cat. No. | Dia. | Wattage | Voltage | Watts/Inch | Weight | Leads | Fittings |
4" 4" 4" 4" 4" 4" 5" 5" 5" 5" 5" 5" 6" 6" 6" 6" 6" 6" |
SAH37-4-2 SAH37-4MF-2 SAH37-4-1 SAH37-4MF-1 SAH37-4-2 SAH37-4MF-2 SAH50-5-2 SAH50-5MF-2 SAH50-5-1 SAH50-5MF-1 SAH50-5-2 SAH50-5MF-2 SAH75-6-2 SAH75-6MF-2 SAH75-6-1 SAH75-6MF-1 SAH75-6-2 SAH75-6MF-2 |
3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" |
50 50 200 200 200 200 100 100 400 400 400 400 190 190 750 750 750 750 |
120 120 120 120 240 240 120 120 120 120 240 240 120 120 120 120 240 240 |
14 14 57 57 57 57 22 22 88 88 88 88 34 34 136 136 136 136 |
.12 .18 .12 .18 .12 .18 .18 .25 .18 .25 .18 .25 .43 .68 .43 .68 .43 .68 |
12" 12" 12" 12" 12" 12" 12" 12" 12" 12" 12" 12" 12" 12" 12" 12" 12" 12" |
1/4"NPT 1/4"NPT 1/4"NPT 1/4"NPT 1/4"NPT 1/4"NPT 3/8"NPT 3/8"NPT 3/8"NPT 3/8"NPT 3/8"NPT 3/8"NPT 3/8"NPT 3/4"NPT 3/4"NPT 3/4"NPT 3/4"NPT 3/4"NPT |
High Volume - High Heat
A typical pure flow system with limits and contols. This ST. ST. heater produces pure flow qualities by not allowing the air or gas to pass directly over the resistance wire, ceramics or mica. It is suitable for LN2 liquids, pressures up to 100 psi, temperatures up to 800°F (430°C), very popular in laboratory and semi-conductor applications.